labCOMPACT12 II and labCOMPACT24 II – Compact solution for multi-channel data acquisition

Front view of multi-channel frontend labCOMPACT12
front view of labCOMPACT

labCOMPACT II is a compact and simplified second-generation HEADlab system with a... 

labCOMPACT II is a compact and simplified second-generation HEADlab system with a greatly improved frequency range and very high possible sampling rates thanks to the powerful HEADlink 2.0 protocol. It combines the basic functions of a controller with a multi-channel module for analog and ICP sensors in a single module. This "single-unit" system is a convenient solution for multi-channel analysis, particularly for the acoustic optimization of household and office appliances. The handy labCOMPACT II systems are also characterized by high phase fidelity of the 32-bit data and a signal-to-noise ratio of 109 dB(A).

  • labCOMPACT12 II can record 12 channels with a sampling rate of up to 102.4 kHz or 6 channels up to 204.8 kHz 
  • labCOMPACT24 II can record 24 channels with a sampling rate of up to 51.2 kHz or 12 channels up to 102.4 kHz 

The Recorder of ArtemiS SUITE serves for data acquisition and controlling and configuring the labCOMPACT II systems. In combination with a power module, labCOMPACT12 II and labCOMPACT24 II can be used for several hours without an external power supply. Both systems can be quickly and easily expanded with an additional HEADlab module. The direct connection to a notebook or PC via USB or LAN ensures secure and stable data transfer.

plus Less

labCOMPACT II is a compact and simplified second-generation HEADlab system with a greatly improved frequency range and very high possible sampling rates thanks to the powerful HEADlink 2.0 protocol. It combines the basic functions of a controller with a multi-channel module for analog... 

labCOMPACT II is a compact and simplified second-generation HEADlab system with a greatly improved frequency range and very high possible sampling rates thanks to the powerful HEADlink 2.0 protocol. It combines the basic functions of a controller with a multi-channel module for analog and ICP sensors in a single module. This "single-unit" system is a convenient solution for multi-channel analysis, particularly for the acoustic optimization of household and office appliances. The handy labCOMPACT II systems are also characterized by high phase fidelity of the 32-bit data and a signal-to-noise ratio of 109 dB(A).

  • labCOMPACT12 II can record 12 channels with a sampling rate of up to 102.4 kHz or 6 channels up to 204.8 kHz 
  • labCOMPACT24 II can record 24 channels with a sampling rate of up to 51.2 kHz or 12 channels up to 102.4 kHz 

The Recorder of ArtemiS SUITE serves for data acquisition and controlling and configuring the labCOMPACT II systems. In combination with a power module, labCOMPACT12 II and labCOMPACT24 II can be used for several hours without an external power supply. Both systems can be quickly and easily expanded with an additional HEADlab module. The direct connection to a notebook or PC via USB or LAN ensures secure and stable data transfer.

plus Less

Highlights

  • “Single-unit” system for precise data acquisition in multi-channel applications
  • Compact, robust and silent
  • High signal-to-noise ratio of 109 dB(A)
  • Easy to expand with further HEADlab modules
  • Sampling rate of up to 204.8 kHz for six channels
  • Connection to a PC via USB or LAN for secure and stable data transfer

Applications

  • Acoustic multi-channel analysis in the development and optimization of household appliances and office equipment
  • Convenient and efficient multi-channel analysis with only one mobile data acquisition unit
  • Sound power measurements

Features

  • Multi-channel data acquisition with only one device for 12 or 24 analog/ICP® sensors
  • Handy, compact and robust HEADlab II housing with tried-and-tested locking technology
  • Silent (without fans)
  • Expandable with HEADlab modules
  • Binaural recording technology with HSU III.2 artificial head series
  • 32-bit data with high phase accuracy
  • Maximum sampling rate of 204.8 kHz
  • Frequency range 0 Hz to 86.4 kHz
  • High signal-to-noise ratio of 109 dB(A)
  • Coupling: AC, DC, ICP, ICP DC
  • Analog high-pass filter – 0.14 Hz in AC mode and 22 Hz (switchable by channel)
  • Connection of TEDS sensors
  • Connection to laptop or PC via USB or LAN
  • Low energy consumption of 11.5/18 W (labCOMPACT12) or 14/22 W (labCOMPACT24) in stand-alone mode/connected to all sensors
  • Power supply via the labPWR power modules or power supply
  • Electrical isolation between signal inputs, PC connection, and power supply
  • Can be used for several hours without an external power supply

Relevant Products

ArtemiS SUITE
(ArtemiS SUITE,SUITE,ArtemiS,50000,50000N,50000N+,9346,9347)
ArtemiS SUITE Modules
(ArtemiS SUITE Modules,ArtemiS Modules,SUITE Modules,Modules,50000,50010,50020,50030,50100,51001,51002,51003,51004,51005,51006,51007,51101,51102,51103,51104,51106,51201,51202,51203,50040,51706,50080,50200,50210,50300,51301,51304,51305,51701,51702,51703,51704,51705,51801,50050,50220,51302,51303,50400,50410,50420,50430,50610,50620,50110,50190,50500,51501,51502,50570)
Compact Analysis
(Compact Analysis,50100)
HEAD Companion
(HEAD Companion,Companion,4906)
HEADlab II
(3700,1520,1574,3760,3769,3562)
HEADlab Modules
(headlab,modules,headlab modules,3794,3725,3702,3704,3741,3743,3710,3754,3732,3711,3712,3713,3705,3727,3726,3753,3755,3728,3752,3705,3731,3731-V1,3732,3732-V1)
HSU III.2, HSU III.3
(HSU III.2,HSU III.3,HSU III,HSU 3,HSU,artificial head,head,binaural,1391,1326,1520,1574,1967)
HMS V
(HMS V,HMS 5,HMS,artificial head,head,binaural,1500,1502,1520,1574,1967)